Air & Gas Systems
 
Need some help? (832) 467-9955  

KTC Series Vacuum Pump


Products :: Vacuum Pumps :: Kinney® Rotary Piston Vacuum Pumps :: KTC Series
  Kinney® KTC™ rotary piston vacuum pumps achieve the lowest possible pressures from mechanical pumps and are recommended for applications where the operating pressure is below 0.1 Torr (0.13 mbar).

As there is no metal-to-metal contact from the clearances being filled with oil, these two-stage pumps are extremely rugged and reliable.

Adjustable gas ballast valves are included as standard equipment for handling water and other vapor loads.

As a result of their triplex piston design, KTC pumps are practically vibration-free.
 
   

  • Features
  • Specifications
  • Applications
  • Model Selection
  • Warranty
  • Documents
  • High pumping speed at pressures below 10 microns;
    much lower than attainable with single stage pumps
  • Ultimate Vacuum: 0.2 microns (McLeod Gauge)
  • Positive pressure lubrication assures operation at any pressure up to atmospheric pressure
  • No metal-to-metal contact in pumping chamber
  • Unequalled durability, even in dirty applications
  • Triplex piston design for quiet, vibration-free operation

Performance Specifications:

  • Two Stage Design
  • Capacity: 21 - 107 CFM
  • Maximum Vacuum: 0.0002 Torr
  • Evacuating Refrigeration Systems
  • Liquid Gas Storage
  • Brake Filling Systems
  • Low Pressure Chemical Vapor Deposition
  • Silicon Crystal Growing
  • Leak Detection

The following table will help you select which model can best fit your application:

Model CFM / m³/h HP / kW
KTC-21 21/35 1.5/1.1
KTC-60 60/102 3.0/2.2
KTC-112 107/182 7.5/5.5

 

Every Tuthill Vacuum Pump is backed by the Tuthill Vacuum & Blower Systems limited warranty:

Type of Application

Atmospheric Air or Process Air without Liquids Present:

Process Gases Other than Air, or Any Liquid Injected Application:

24 months from date of shipment, or 18 months after initial startup date, whichever occurs first.

18 months from date of shipment, or 12 months after initial startup date, whichever occurs first

 
 