M-D Standard Blower Packages
|
Products :: Blower Packages :: M-D Standard Blower Packages |
 |
| |
Engineered with the industry recognized PD Plus™ & Equalizer RM™ blowers, these versatile packages have nearly 250,000 possible configurations.
See table below for more information and specifications.
|
 |
 |
- Specifications
- Features
- Applications
- Warranty
- Drawings
Performance Specifications:
- Flow range: 8 - 4200 CFM (14 - 7100 m³/h)
- Pressure range: up to 15 PSIG (1.03 bar g)
- Vacuum range: up to 16" Hg (540 mbar g)
- Quick availability - as little as two weeks after receipt of order
- Welded, structural steel base
- Easy access to service areas
- Factory assembled & factory warranted
- Available for PD Plus, AcousticAir or Equalizer blowers
- Versatile configurations
- Soil Vapor Extraction
- Oil-Free Handling Fuel, Utility or Process Gases
- Fluid Bed Combustion
- Pneumatic Conveying
- Fluidization/Agitation of Dense Powders
- Vapor Recovery
- Digester Gas Processing
- Steam Compression
- High-Performance Applications
- Pressure Boosting
Every Tuthill Blower Package is backed by the Tuthill Vacuum & Blower Systems limited warranty:
| Type of Application |
Atmospheric Air or Process Air without Liquids Present: |
Process Gases Other than Air, or Any Liquid Injected Application: |
24 months from date of shipment, or 18 months after initial startup date, whichever occurs first. |
18 months from date of shipment, or 12 months after initial startup date, whichever occurs first |
| Drawing |
Blower Models |
Series |
CFM (m³/h) |
HP |
Flow/ Base |
Silencers |
WCEP |
Ext. Lube |
| 3202, 3204 |
| 3200 HV2 |
3202, 3204 |
17/57/64 |
8-100 (14-170) |
2-10 |
horizontal, no legs |
none |
no |
no |
| 3200 VV1 |
3202, 3204 |
46/81 |
8-100 (14-170) |
2-10 |
vertical, no legs |
none |
no |
no |
| 3200 VV1L |
3202, 3204 |
46/81 |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
none |
no |
no |
| 3200 VV1A |
3202, 3204 |
84/85 |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
inlet, discharge |
no |
no |
| 3200 VV1A-L |
3202, 3204 |
46E/81E |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
inlet, discharge |
no |
yes |
| 3200 VV1A-E |
3202, 3204 |
46E/81E |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
inlet, discharge |
yes |
no |
| 3200 VV1A-DS |
3202, 3204 |
46/81 |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
discharge |
no |
no |
| 3200 VV1A-DSE |
3202, 3204 |
46E/81E |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
discharge |
yes |
no |
| 3200 VV1A-ISE |
3202, 3204 |
46E/81E |
8-100 (14-170) |
2-10 |
vertical, w/ legs |
inlet |
yes |
no |
| Drawing |
Blower Models |
Series |
CFM (m³/h) |
HP |
Flow/ Base |
Silencers |
WCEP |
Ext. Lube |
| 3206, 3210 |
| 3200 HV3 |
3206, 3210 |
17/57/64 |
26-300 (44-510) |
3-20 |
horizontal, no legs |
none |
no |
no |
| 3200 VV2 |
3206, 3210 |
46/81 |
26-300 (44-510) |
3-25 |
vertical, no legs |
none |
no |
no |
| 3200 VV2-L |
3206, 3210 |
84/85 |
26-300 (44-510) |
3-25 |
vertical, no legs |
none |
no |
yes |
| 3200 VV2L-L |
3206, 3210 |
84/85 |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
none |
no |
yes |
| 3200 VV2L-E |
3206, 3210 |
46E/81E |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
none |
yes |
no |
| 3200 VV2A |
3206, 3210 |
46/81 |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
inlet, discharge |
no |
no |
| 3200 VV2A-L |
3206, 3210 |
84/85 |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
inlet, discharge |
no |
yes |
| 3200 VV2A-E |
3206, 3210 |
46E/81E |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
inlet, discharge |
yes |
no |
| 3200 VV2A-DS |
3206, 3210 |
46/81 |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
discharge |
no |
no |
| 3200 VV2A-DSL |
3206, 3210 |
84/85 |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
discharge |
no |
yes |
| 3200 VV2A-DSE |
3206, 3210 |
46E/81E |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
discharge |
yes |
no |
| 3200 VV2A-IS |
3206, 3210 |
46/81 |
26-300 (44-510) |
3-25 |
vertical, w/ legs |
inlet |
no |
no |
| Drawing |
Blower Models |
Series |
CFM (m³/h) |
HP |
Flow/ Base |
Silencers |
WCEP |
Ext. Lube |
| 4006, 4009, 4012 |
| 4000 HV1 |
4006, 4009, 4012 |
17/57 |
55-600 (95-1020) |
5-10 |
horizontal no legs |
none |
no |
no |
| 4000 VV1 |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
5-10 |
vertical no legs |
none |
no |
no |
| 4000 VV1L |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
5-10 |
vertical w/ legs |
none |
no |
no |
| 4000 VV1A |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
5-10 |
vertical w/ legs |
inlet, discharge |
no |
no |
| 4000 VV1A-L |
4006, 4009, 4012 |
84/85 |
55-600 (95-1020) |
5-10 |
vertical w/ legs |
inlet, discharge |
no |
yes |
| 4000 VV1A-DS |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
5-10 |
vertical w/ legs |
discharge |
no |
no |
| 4000 VV1A-DSL |
4006, 4009, 4012 |
17/57 |
55-600 (95-1020) |
5-10 |
vertical w/ legs |
discharge |
no |
yes |
| 4000 VV1A-IS |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
5-10 |
vertical w/ legs |
inlet |
no |
no |
| Drawing |
Blower Models |
Series |
CFM (m³/h) |
HP |
Flow/ Base |
Silencers |
WCEP |
Ext. Lube |
| 4006, 4009, 4012 continued |
| 4000 HV2 |
4006, 4009, 4012 |
17/57 |
55-600 (95-1020) |
15-30 |
horizontal no legs |
none |
no |
no |
| 4000 VV2 |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
15-30 |
vertical no legs |
none |
no |
no |
| 4000 VV2L |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
none |
no |
no |
| 4000 VV2L-E |
4006, 4009, 4012 |
46E/81E |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
none |
yes |
no |
| 4000 VV2A |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
inlet, discharge |
no |
no |
| 4000 VV2A-L |
4006, 4009, 4012 |
84/85 |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
inlet, discharge |
no |
yes |
| 4000 VV2A-E |
4006, 4009, 4012 |
46E/81E |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
inlet, discharge |
yes |
no |
| 4000 VV2A-DS |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
discharge |
no |
no |
| 4000 VV2A-IS |
4006, 4009, 4012 |
46/81 |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
inlet |
no |
no |
| 4000 VV2A-ISE |
4006, 4009, 4012 |
46E/81E |
55-600 (95-1020) |
15-30 |
vertical w/ legs |
inlet |
yes |
no |
| Drawing |
Blower Models |
Series |
CFM (m³/h) |
HP |
Flow/ Base |
Silencers |
WCEP |
Ext. Lube |
| 4606, 4609, 4612 |
| 4600 VV1A |
| 4600 VV2A |
| 5507, 5509, 5511, 5514, 5516 |
| 5500 HV1 |
| 5500 HV2 |
| 5500 VV1 |
| 5500 VV1A |
| 5500 VV1A-DS |
| 5500 VV1A-E |
| 5500 VV1L |
| 5500 VV1L-L |
| 5500 VV2 |
| 5500 VV2A |
| 5500 VV2A-DSE |
| 5500 VV2A-DS |
| 5500 VV2A-E |
| 5500 VV2A-L |
| 5500 VV2L |
| 5500 VV2L-L |
| 5500 VV3 |
| 5500 VV3A |
| 5500 VV3A-DS |
| 5500 VV3A-E |
| 5500 VV3A-IS |
| 5500 VV3L |
| 5500 VV3L-E |
| 5500v VV3L-L |
| 5500 VV4L |
| 5500 VV5L |
| 5500 VV5L-E |
| 5500 VV6L |
| 5500 VV6L-E |
| 7010, 7013, 7017, 7021 |
| 7000 VV1A |
| 7000 VV1A-DS |
| 7000 VV1L |
| 7000 VV2 |
| 7000 VV2A |
| 7000 VV2A-DS |
| 7000 VV3A |
|
|
|